NFM Inc, Santa Monica, CA, USA / Phone:(310) 564-6412 / FAX:(310) 802-3917 / www.nfminc.com
blueline

Optional outputs for M5 Sensors

M5 non-standard Voltage outputs

The M5 can be delivered with other Voltage levels than the standard ±10V.

Voltage (0..+10V)

closest = 0 V, reference distance = +5 V, farest =+10 V

Voltage (±5V)

closest = -5 V, reference distance = 0 V, farest =+5 V

other levels upon request.

M5 non-standard Thickness output

Thickness measurement can be achieved by connecting two M5's opposite synchronizing ±10V.

Voltage (0..+10V)

thinnest = 0 V, thickest =+10 V

Voltage (±5V)

closest = -5 V, reference distance = 0 V, farest =+5 V

M5 non-standard current outputs

For long distances or noisy environment, a current (4..20mA) version is available.(*)

Current

closest = 4 mA, reference distance = +12mA, farest =+20mA

Voltage (±5V)

closest = 0mA, reference distance = +10mA, farest =+20mA

Connector (DB25)

Look for the special connector pin assignment

(*) except for M500
other levels upon request.

M5 non-standard Serial output

A digital (serial) output with internal high precision A/D converter is available.(*)

Serial Data

12 Bits, spread over 2 Bytes, 8 N 1

Connector (DB25)

Look for the special connector pin assignment

Dip switch settings

on

(*) except for M500

M5 non-standard Relay outputs

Instead of the standard (+24V) outputs, the three digital
"MIN", "OK" and "MAX" can be ordered with SPCO relays
(*)

Switching
 outputs
MIN

Relay 0.5A / 100V~, n.o.
closed if below MIN
(**), yellow LED on

OK

Relay 0.5A / 100V~, n.o.
closed if in-between MIN and MAX levels
(**), green LED on

MAX

Relay 0.5A / 100V~, n.o.
closed if above MAX
(**), red LED on

Connector (DB25)

Look for the special connector pin assignment

(*) except for M500
(**) Min and Max levels can be set with 2 potentiometers